  1. 12
      License.txt
  2. 48
      README.md
  3. 172
      lutron-dmx-control.py
  4. 13
      lutron-dmx-control@.service
  5. 13
      olad@.service

12
License.txt

@ -0,0 +1,12 @@
Copyright (c) 2019, Mr. Gecko's Media (James Coleman)
All rights reserved.
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

48
README.md

@ -0,0 +1,48 @@
This project is designed to control the GRAFIK Eye QS Control panel via the QSE-CI-NWK-E with the serial interface. The project is designed to use the OLA (https://www.openlighting.org/) project to use either a DMX device to a network DMX protocol to control the 6 available zones.
I designed this software for use on a Raspberry Pi using the 2019-07-10-raspbian-buster-lite release and OLA at https://github.com/OpenLightingProject/ola/tree/dc40569a7ef2512c7c9459a94c9dc4292d809262 compiled and installed using instructions at https://www.openlighting.org/ola/linuxinstall/
# Configuration
Once OLA is installed, run it using `olad -l 3` and then edit the configuration files in `.ola/` to disable the modules which are not used as some of them will take the serial device. Once configured, run `olad -l 3` again and visit the raspberry pi's IP address at port 9090 in your browser to configure the DMX universe you are going to use. Once configured, you can then test this software by changing the configuration portion of the code.
Trick to disable all modules except the one you are using.
```bash
sed -i '/enabled\s=/c\enabled = false' ~/.ola/*.conf
sed -i '/enabled\s=/c\enabled = true' ~/.ola/ola-e131.conf
```
# Installation
Install Python/needed modules.
```bash
apt install python3-pip python3-serial
pip3 install ola
```
Copy lutron-dmx-control@.service and olad@.service to /etc/systemd/system/ and run the following to enable/start.
```bash
systemctl daemon-reload
systemctl enable olad@pi
systemctl start olad@pi
systemctl enable lutron-dmx-control@pi
systemctl start lutron-dmx-control@pi
```
# Recommend
Enable watchdog on the Raspberry Pi to auto reboot upon system crashes.
Edit `/boot/config.txt` and add under the `[all]` section.
```
watchdog=on
```
Edit `/etc/systemd/system.conf` and uncomment `RuntimeWatchdogSec` and set it as follows.
```
RuntimeWatchdogSec=10s
```
After configuring, reboot.

172
lutron-dmx-control.py

@ -0,0 +1,172 @@
# lutron-dmx-control
#
# Copyright (c) 2019, Mr. Gecko's Media (James Coleman)
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
#
# 1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
#
# 2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following
# disclaimer in the documentation and/or other materials provided with the distribution.
#
# 3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products
# derived from this software without specific prior written permission.
#
# THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
# INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
# SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
# LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT,
# STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF
# ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
#
from ola.ClientWrapper import ClientWrapper
import serial
import io
import _thread
import threading
import time
# Documentation
# This program is designed to use the Open Lighting Arcretechture (OLA) to receive a DMX signal
# and translate to commands to control the 6 dimiable zones on the Lutron GRAFIK Eye QS Control panel
# through the use of a QSE-CI-NWK-E. This program uses the serial port for reliability.
# Configuration
# Serial port device to use to communicate with Lutron's QSE NWK.
QSE_NWK_DEVICE = "/dev/ttyUSB0"
# Set baud rate on Lutron's QSE NWK.
QSE_NWK_BAUD = 115200
# DMX Universe in OLA that is used.
DMX_UNIVERSE = 3
# The starting address.
DMX_START_ADDRESS = 0
#Verbosity
VERBOSE=1
# Variables used at run time, do not adjust.
serialSession = None
currentValues = [0,0,0,0,0,0]
sendAllDataThisTime = True
controlDisabled = False
# To prevent data from overlapping which is known to crash the QSE NWK, we implement a thread lock which must be released before being obtained.
dataLock = threading.Lock()
# This fucnction translates the 0-255 signal from DMX to 0.00 to 100.00 signal used by Lutron,
# and it sends the appropiate command to the QSE NWK to change the brightness level of a zone.
def SetZone(zone, value):
global serialSession, currentValues, sendAllDataThisTime, controlDisabled
# We only want to translate a level of it has not already been sent to the zone,
# or if we want to send all data this time. However we do not want to send the level
# if the controls has been disabled by the designated button on the control panel.
if (currentValues[zone-1]==value and not sendAllDataThisTime) or controlDisabled:
return
# Update the array of current values.
currentValues[zone-1] = value
# Translate to the command.
command = "#DEVICE,1,%d,14,%.2f,00:00" % (zone,round((value/255.00)*100,2))
if VERBOSE>=1:
print(command)
# Send to the QSE NWK.
serialSession.write(bytes(command+"\n\r", 'utf-8'))
def NewData(data):
global sendAllDataThisTime, dataLock
# Acquire the lock for the thread to prevent data from overlapping.
dataLock.acquire()
if VERBOSE>=2:
print(data)
# Send the new levels to each zone via the QSE NWK.
SetZone(1,data[DMX_START_ADDRESS+0])
SetZone(2,data[DMX_START_ADDRESS+1])
SetZone(3,data[DMX_START_ADDRESS+2])
SetZone(4,data[DMX_START_ADDRESS+3])
SetZone(5,data[DMX_START_ADDRESS+4])
SetZone(6,data[DMX_START_ADDRESS+5])
# Reset the flag of send all data to false as we would have sent all data this time.
sendAllDataThisTime = False
# Allow the next command call to follow through by releasing the lock.
dataLock.release()
# This function reads the serial data from the QSE NWK line by line and performs a few functions based on response.
def QSE_Read():
global serialSession, controlDisabled
# Creates a bufferred reader for the serial input.
sio = io.TextIOWrapper(io.BufferedReader(serialSession))
# We want to run this forever as we are in a thread.
while True:
# Gets the next available line from the QSE NWK and filter out the QSE prompt and any new line characters.
line = sio.readline().replace("QSE>","").rstrip()
if line=="":
continue
# If the command not found error is returned, this is either due to
# the Lutron GRAFIK Eye QS Control panel not being assigned an integration ID of 1,
# or due to a bug which needs the QSE NWK rebooted to fix. We attempt to reboot
# to attempt to automatically fix the bug.
if line=="~ERROR,6":
if VERBOSE>=2:
print("Error occurred, rebooting QSE NWK.")
# Send the reboot command.
serialSession.write(bytes("#RESET,0\n\r", 'utf-8'))
# If the all zone up button is pressed, we disable control from the program to allow someone to manually control zones.
if line=="~DEVICE,1,74,3":
if VERBOSE>=2:
print("Received disable signal.")
controlDisabled = True
# If the all zone down button is pressed, we re-enable the programs control of the zones.
if line=="~DEVICE,1,75,3":
if VERBOSE>=2:
print("Received enable signal.")
controlDisabled = False
sendAllDataThisTime = True
if VERBOSE>=1:
print(line)
# Reset the send all data flag every 10 seconds to ensure all zones have the correct value set.
def sendAllDataReset():
global sendAllDataThisTime
while True:
time.sleep(10)
if VERBOSE>=3:
print("Resetting flag to send all data")
sendAllDataThisTime = True
# Connect to the QSE NWK by using the serial port.
print("Connecting to QSE NWK at: "+QSE_NWK_DEVICE)
with serial.Serial(QSE_NWK_DEVICE, QSE_NWK_BAUD, timeout=2) as ser:
serialSession = ser
# If the serial session is still set to None, we did not correctly connect.
if serialSession == None:
print("Failed to connect.")
exit(1)
# We connected, so we can open the device.
serialSession.open()
# Now that we are ready to roll, we start the read thread.
_thread.start_new_thread(QSE_Read, ())
# Start the reset send all data thread.
_thread.start_new_thread(sendAllDataReset, ())
# Connect to the DMX universe with the OLA wrapper.
wrapper = ClientWrapper()
client = wrapper.Client()
client.RegisterUniverse(DMX_UNIVERSE, client.REGISTER, NewData)
wrapper.Run()

13
lutron-dmx-control@.service

@ -0,0 +1,13 @@
[Unit]
Description=Lutron DMX Control
After=network.target
[Service]
Type=simple
ExecStart=/usr/bin/python3 /home/%I/lutron-dmx-control.py
Restart=on-failure
RestartSec=10
User=%I
[Install]
WantedBy=multi-user.target

13
olad@.service

@ -0,0 +1,13 @@
[Unit]
Description=OLAD
After=network.target
[Service]
Type=simple
ExecStart=/usr/local/bin/olad -l 3
Restart=on-failure
RestartSec=10
User=%I
[Install]
WantedBy=multi-user.target
Loading…
Cancel
Save